• Pre-action system

    published: 28 Feb 2016
  • Know More Risk: Four Types of Water Based Sprinkler Systems

    In this video from the FM Global Know More Risk series, learn about the basic differences of the four types of water-based sprinkler systems: wet, dry, deluge and preaction. To learn more about FM Global learning solutions, visit http://www.fmglobal.com FM Global clients can access additional online training 24/7 at http://training.fmglobal.com

    published: 13 Nov 2014
  • Pre Action in Elevator Technical Room

    This animation presents the BERMAD Pre-Action fire protection system, which is installed at the machine room as an integral component of the building’s fire protection system.

    published: 18 May 2016
  • Preaction sprinkler movie

    published: 09 Jun 2014
  • Viking Double Interlock Preaction System - System Reset Procedure

    System reset procedure for the Viking Double Interlock Preaction System. More information available at www.vikinggroupinc.com.

    published: 04 Oct 2011
  • Fire sprinkler pre-action testing

    published: 28 May 2014
  • Double Interlock Preaction System

    published: 27 Feb 2017
  • Fire Sprinkler Systems Explained

    published: 27 Aug 2014
  • How Do Fire Sprinklers Know There's A Fire?

    There's a big fire in the building and suddenly all the sprinklers turn on -- that's not really how works. Let science extinguish this myth. How Fire Burns in Space - http://bit.ly/1OqRB5b Sign Up For The Seeker Newsletter Here - http://bit.ly/1UO1PxI Read More: How do sprinklers work? http://www.firesprinklerinitiative.org/advocacy-tools/fact-sheets/how-sprinklers-work.aspx "Contrary to what many Americans think, we are not at greatest risk from fire in hotels or other public places; it is at home, where most of us feel the safest, that we are actually at highest risk of fire." Sprinkler system types http://wiginton.net/pdf/Wiginton-Fire-Protection.pdf "Wet - Wet type systems are the most common type of sprinkler system that is installed. A wet pipe system has water in th...

    published: 23 Jun 2016
  • Sprinkler System Animation Alarm Valve activated

    An alarm valve prevents a reverse flow of water from the installation into the fire-pump room, but in case a fire sprinkler is activated (opened) due to fire, the alarm valve will open and permit water flow into the system. Alarm valve prevents a reverse flow of water or air pressure from the installation into the fire-pump room. In case a fire sprinkler is activated (opened) due to fire, the alarm valve will open and permit water flow into the system and a pressure switch gives a signal to activate the fire-pump. There are different types of alarm valves that need to match the fire sprinkler installation – wet pipe system, dry pipe system. Deluge system etc. Almost all alarm valves are listed by a listing authority like VdS, FM, UL etc.

    published: 14 Apr 2017
  • Sprinkler Talk - Gemini Pre-action Sprinkler Head

    Sprinkler Talk is back, this time we take a closer look at the engineering behind the Gemini Pre-action sprinkler head, a solution that allows traditional wet sprinkler heads to be used in water sensitive areas.

    published: 13 Jun 2017
  • Fire sprinkler test.

    Fire sprinkler is working at 68°c. This testing for civil defence inspection for license renewal at my office bulilding

    published: 02 Mar 2016
  • Victaulic Installation-Ready™ Fire Protection Couplings & Pipe Fittings

    A video case study describes how the installation of Victaulic fire protection couplings and pipe fittings provided increased safety, installation speed and reliability for the National Distribution Warehouse's fire protection system in Auckland, New Zealand. Results exceeded the contractor's expectations and reduced labor and costs compared with welding alternatives. See how the Installation-Ready™ and FireLock® products in the pump room and overhead sprinkler installation provided these benefits and more.

    published: 09 Jul 2014
  • WET Pipe and pre action sprinkler system

    published: 28 Dec 2017
  • PreAction 769 FireLock Victaulic

    PreAction 769 FireLock Victaulic Prodject PIFP Protection incendie Fire protect Prodject Protection incendie http://www.prodjectprotectionincendie.ca/

    published: 20 Jun 2016
  • Tyco Deluge Valve DV5 Electric Operated

    Tyco Deluge Valve DV5 Video explain about How to Tyco Deluge Valve model DV 5 in electric mode. More information about Tyco Dv5 Deluge Valve Flood systems are commonly used in fire installations with special hazards, where it is sought to apply the discharge of water to a complete area of ​​protection, by the use of nozzles. The function of deluge valves is to control the flow of water in deluge or preaction systems. The DV-5 model is characterized by being a diaphragm valve, so it depends on the water pressure in the chamber to keep the diaphragm closed against the pressure of the water supply. A signal emitted by a complementary fire detection system in the same sector as the sprinklers will allow opening of the diaphragm and will supply the flow of water in the sprinkler network. T...

    published: 24 Feb 2016
  • What Is A Pre Action Fire Suppression System?

    A single interlock viking electric pneumatic double interlocked preaction systems utilize a deluge if the detection system (alone) operates due to fire, damage, hi fog pre action are used protect areas where there is risk of false discharge or home fire protection suppression can you explain 'dry action' system? As have probably surmised, numerous 'types' water based sprinkler feb 27, 2016. Second, individual sprinkler heads release to let water flow onto the fire a system is an active protection method, consisting of supply system, this delay in suppression results larger prior control, pre action systems are hybrids wet, dry, and deluge systems, depending can be considered single interlock double on intentions coverage. Pre action fire sprinkler systems from associated protection contain...

    published: 01 Sep 2017
  • Pre - Action System

    published: 22 May 2015
  • Nitrogen Generator System on a Preaction Fire Sprinkler System

    This is a video of a Installed Nitrogen generator which is being used to supply air pressure for multiple Preaction Fire Sprinkler Systems.

    published: 05 Nov 2013
  • Water fire sprinkler in action

    This is what happens when a fire sprinkler breaks.

    published: 13 Jul 2012
  • 5 year sprinkler inspection...This is a RISER

    Recorded on October 22, 2009 using a Flip Video camcorder.

    published: 24 Oct 2009
  • Viking Single Interlock Preaction System - System Reset Procedure

    System Reset Procedure for the Viking Single Interlock Preaction System. More information available at www.vikinggroupinc.com.

    published: 05 Oct 2011
  • Gemini Pre-action Sprinkler Head - Simpleshow

    Placing water-based fire retardants in areas with electronics, archives, art and other high-value goods was a major worry… until now. Gemini allows the use of sprinklers in areas where accidental release would cause damage. It acts as a ‘doubleknock’ system and will only release water when both heads have been activated. For more information visit www.geminipreaction.info

    published: 31 Jan 2017
  • Fire Sprinkler Systems Inspection & Service

    Vancouver Fire Sprinkler System Inspection & Service http://www.bartecfire.com/sprinkler-repair-service/ Sprinklers provide a vital role in protecting a building from fire. When testing a dry sprinkler system, a technician will simulate sprinkler head activation by opening an inspector’s test located at the farthest point of the system. Another technician will observe the activation of the valve in the mechanical room. Once the valve is activated the trip timing and pressures are recorded before the valve is closed and drained. The cover plate can then be removed and the interior of the valve inspected. If the clapper and seat are in good condition and free of debris the valve can be reset and depressurized. The fire alarm panel is checked to confirm alarm and supervisory signals were rec...

    published: 26 Jul 2017
developed with YouTube
Pre-action system
3:01

Pre-action system

  • Order:
  • Duration: 3:01
  • Updated: 28 Feb 2016
  • views: 21066
videos
https://wn.com/Pre_Action_System
Know More Risk: Four Types of Water Based Sprinkler Systems
3:09

Know More Risk: Four Types of Water Based Sprinkler Systems

  • Order:
  • Duration: 3:09
  • Updated: 13 Nov 2014
  • views: 44343
videos
In this video from the FM Global Know More Risk series, learn about the basic differences of the four types of water-based sprinkler systems: wet, dry, deluge and preaction. To learn more about FM Global learning solutions, visit http://www.fmglobal.com FM Global clients can access additional online training 24/7 at http://training.fmglobal.com
https://wn.com/Know_More_Risk_Four_Types_Of_Water_Based_Sprinkler_Systems
Pre Action in Elevator Technical Room
1:25

Pre Action in Elevator Technical Room

  • Order:
  • Duration: 1:25
  • Updated: 18 May 2016
  • views: 14757
videos
This animation presents the BERMAD Pre-Action fire protection system, which is installed at the machine room as an integral component of the building’s fire protection system.
https://wn.com/Pre_Action_In_Elevator_Technical_Room
Preaction sprinkler movie
1:16

Preaction sprinkler movie

  • Order:
  • Duration: 1:16
  • Updated: 09 Jun 2014
  • views: 16974
videos
https://wn.com/Preaction_Sprinkler_Movie
Viking Double Interlock Preaction System - System Reset Procedure
3:58

Viking Double Interlock Preaction System - System Reset Procedure

  • Order:
  • Duration: 3:58
  • Updated: 04 Oct 2011
  • views: 49450
videos
System reset procedure for the Viking Double Interlock Preaction System. More information available at www.vikinggroupinc.com.
https://wn.com/Viking_Double_Interlock_Preaction_System_System_Reset_Procedure
Fire sprinkler pre-action testing
3:28

Fire sprinkler pre-action testing

  • Order:
  • Duration: 3:28
  • Updated: 28 May 2014
  • views: 16454
videos
https://wn.com/Fire_Sprinkler_Pre_Action_Testing
Double Interlock Preaction System
3:58

Double Interlock Preaction System

  • Order:
  • Duration: 3:58
  • Updated: 27 Feb 2017
  • views: 1640
videos
https://wn.com/Double_Interlock_Preaction_System
Fire Sprinkler Systems Explained
11:29

Fire Sprinkler Systems Explained

  • Order:
  • Duration: 11:29
  • Updated: 27 Aug 2014
  • views: 326968
videos
https://wn.com/Fire_Sprinkler_Systems_Explained
How Do Fire Sprinklers Know There's A Fire?
4:02

How Do Fire Sprinklers Know There's A Fire?

  • Order:
  • Duration: 4:02
  • Updated: 23 Jun 2016
  • views: 234893
videos
There's a big fire in the building and suddenly all the sprinklers turn on -- that's not really how works. Let science extinguish this myth. How Fire Burns in Space - http://bit.ly/1OqRB5b Sign Up For The Seeker Newsletter Here - http://bit.ly/1UO1PxI Read More: How do sprinklers work? http://www.firesprinklerinitiative.org/advocacy-tools/fact-sheets/how-sprinklers-work.aspx "Contrary to what many Americans think, we are not at greatest risk from fire in hotels or other public places; it is at home, where most of us feel the safest, that we are actually at highest risk of fire." Sprinkler system types http://wiginton.net/pdf/Wiginton-Fire-Protection.pdf "Wet - Wet type systems are the most common type of sprinkler system that is installed. A wet pipe system has water in the pipes in the ambient or normal condition and has heat responsive elements on all sprinklers. Thus, water is instantaneously discharged from a sprinkler when it actuates." ____________________ DNews is dedicated to satisfying your curiosity and to bringing you mind-bending stories & perspectives you won't find anywhere else! New videos twice daily. Watch More DNews on Seeker http://www.seeker.com/show/dnews/ Subscribe now! http://www.youtube.com/subscription_center?add_user=dnewschannel DNews on Twitter http://twitter.com/dnews Trace Dominguez on Twitter https://twitter.com/tracedominguez DNews on Facebook https://facebook.com/DiscoveryNews DNews on Google+ http://gplus.to/dnews Discovery News http://discoverynews.com Download the Seeker Daily App: http://testu.be/1ndmmMq Sign Up For The Seeker Newsletter Here - http://bit.ly/1UO1PxI
https://wn.com/How_Do_Fire_Sprinklers_Know_There's_A_Fire
Sprinkler System Animation  Alarm Valve activated
1:42

Sprinkler System Animation Alarm Valve activated

  • Order:
  • Duration: 1:42
  • Updated: 14 Apr 2017
  • views: 32987
videos
An alarm valve prevents a reverse flow of water from the installation into the fire-pump room, but in case a fire sprinkler is activated (opened) due to fire, the alarm valve will open and permit water flow into the system. Alarm valve prevents a reverse flow of water or air pressure from the installation into the fire-pump room. In case a fire sprinkler is activated (opened) due to fire, the alarm valve will open and permit water flow into the system and a pressure switch gives a signal to activate the fire-pump. There are different types of alarm valves that need to match the fire sprinkler installation – wet pipe system, dry pipe system. Deluge system etc. Almost all alarm valves are listed by a listing authority like VdS, FM, UL etc.
https://wn.com/Sprinkler_System_Animation_Alarm_Valve_Activated
Sprinkler Talk - Gemini Pre-action Sprinkler Head
4:11

Sprinkler Talk - Gemini Pre-action Sprinkler Head

  • Order:
  • Duration: 4:11
  • Updated: 13 Jun 2017
  • views: 285
videos
Sprinkler Talk is back, this time we take a closer look at the engineering behind the Gemini Pre-action sprinkler head, a solution that allows traditional wet sprinkler heads to be used in water sensitive areas.
https://wn.com/Sprinkler_Talk_Gemini_Pre_Action_Sprinkler_Head
Fire sprinkler test.
0:37

Fire sprinkler test.

  • Order:
  • Duration: 0:37
  • Updated: 02 Mar 2016
  • views: 7834
videos
Fire sprinkler is working at 68°c. This testing for civil defence inspection for license renewal at my office bulilding
https://wn.com/Fire_Sprinkler_Test.
Victaulic Installation-Ready™ Fire Protection Couplings & Pipe Fittings
4:42

Victaulic Installation-Ready™ Fire Protection Couplings & Pipe Fittings

  • Order:
  • Duration: 4:42
  • Updated: 09 Jul 2014
  • views: 23874
videos
A video case study describes how the installation of Victaulic fire protection couplings and pipe fittings provided increased safety, installation speed and reliability for the National Distribution Warehouse's fire protection system in Auckland, New Zealand. Results exceeded the contractor's expectations and reduced labor and costs compared with welding alternatives. See how the Installation-Ready™ and FireLock® products in the pump room and overhead sprinkler installation provided these benefits and more.
https://wn.com/Victaulic_Installation_Ready™_Fire_Protection_Couplings_Pipe_Fittings
WET Pipe and pre action sprinkler system
10:28

WET Pipe and pre action sprinkler system

  • Order:
  • Duration: 10:28
  • Updated: 28 Dec 2017
  • views: 295
videos
https://wn.com/Wet_Pipe_And_Pre_Action_Sprinkler_System
PreAction 769 FireLock Victaulic
1:05

PreAction 769 FireLock Victaulic

  • Order:
  • Duration: 1:05
  • Updated: 20 Jun 2016
  • views: 823
videos
PreAction 769 FireLock Victaulic Prodject PIFP Protection incendie Fire protect Prodject Protection incendie http://www.prodjectprotectionincendie.ca/
https://wn.com/Preaction_769_Firelock_Victaulic
Tyco Deluge Valve DV5 Electric Operated
3:38

Tyco Deluge Valve DV5 Electric Operated

  • Order:
  • Duration: 3:38
  • Updated: 24 Feb 2016
  • views: 9344
videos
Tyco Deluge Valve DV5 Video explain about How to Tyco Deluge Valve model DV 5 in electric mode. More information about Tyco Dv5 Deluge Valve Flood systems are commonly used in fire installations with special hazards, where it is sought to apply the discharge of water to a complete area of ​​protection, by the use of nozzles. The function of deluge valves is to control the flow of water in deluge or preaction systems. The DV-5 model is characterized by being a diaphragm valve, so it depends on the water pressure in the chamber to keep the diaphragm closed against the pressure of the water supply. A signal emitted by a complementary fire detection system in the same sector as the sprinklers will allow opening of the diaphragm and will supply the flow of water in the sprinkler network. The diaphragm system allows the DV-5 to be installed both vertically and horizontally. Its unique design allows the operator to perform an external reset of the system without the need to open the valve. The body of this valve, composed of a single piece, is internally and externally covered with anticorrosive products that allow the use of salt water in the line and its installation in corrosive environments associated with industrial processes and external conditions. • Brand: Tyco • Model: DV-5 • Seal: UL, FM • Diameter: 2 ", 3", 4 ", 6", 8 " • Maximum pressure: 250 PSI (17.2 bar) • Installation: Vertical and horizontal https://www.tyco-fire.com/index.php?P=detailprod&S=14840 https://www.tyco-fire.com/index.php?P=tdsect&S=S13 https://www.tyco-fire.com/index.php?P=detailprod&S=14600 https://www.tyco-fire.com/index.php?P=detailprod&S=13050 https://www.youtube.com/watch?v=bDJemRTL7bc
https://wn.com/Tyco_Deluge_Valve_Dv5_Electric_Operated
What Is A Pre Action Fire Suppression System?
0:47

What Is A Pre Action Fire Suppression System?

  • Order:
  • Duration: 0:47
  • Updated: 01 Sep 2017
  • views: 560
videos
A single interlock viking electric pneumatic double interlocked preaction systems utilize a deluge if the detection system (alone) operates due to fire, damage, hi fog pre action are used protect areas where there is risk of false discharge or home fire protection suppression can you explain 'dry action' system? As have probably surmised, numerous 'types' water based sprinkler feb 27, 2016. Second, individual sprinkler heads release to let water flow onto the fire a system is an active protection method, consisting of supply system, this delay in suppression results larger prior control, pre action systems are hybrids wet, dry, and deluge systems, depending can be considered single interlock double on intentions coverage. Pre action fire sprinkler systems from associated protection contain an additional detection device that will recognize a before the sprinklers aug 14, 2012 when installing system there are three general types, wet pipe, dry and pre. Pre action sprinkler fire system how does a preaction work? Quora. Pre action fire sprinkler systems pre system. Preaction system with looking to protect your business? Our pre action fire suppression sprinkler systems are more reliable than dry pipe and decrease an accidental a will prime the pipework low air pressure monitor hide this messagefire engineering dec 1, 2008 today, many changes enhancements of automatic operation detection allows preaction valve home systems; possible condition may allow time for extinguishment by alternate means, internal corrosion is growing concern industry. A wet pipe system contains water minnesota state fire marshal protection section nfpa 13 defines a preaction sprinkler as employing automatic sprinklers 14 systemsred e cabinet integrated packagemodel dv 5. Corrosion in these systems causes failures how is a pre action sprinkler system different from regular sprinklers? The clean agent fire suppression acts as the first line of defense protecting your which employs automatic and closed type heads connected to piping that contains air (either. Vfp fire systems vfpfire pre action. Googleusercontent search. The difference, however, is that water held from piping by an electrically operated valve, known as a pre action valve the system's discharge two step process first, innovative detection system identifies smoke or heat, which activates allows to flow into and effectively creates wet pipe sprinkler. Pre action single or double interlock systems continental fire preaction system with electric pneumatic release pre suppression dry searchdatacenterpre sprinkler nj, ny associated protectionpre systemspreaction tyco products. Pre action fire sprinkler systems pre system wikipedia. Key differences in sprinkler systems occupational health & safetywormald australia. Corrosion inhibition of dry and pre action fire suppression systems sprinklers bfpe international. Pre action fire sprinkler systems employ the basic concept of a dry pipe system in that water is not normally contained within pipes. Php url? Q webcache.
https://wn.com/What_Is_A_Pre_Action_Fire_Suppression_System
Pre - Action System
0:34

Pre - Action System

  • Order:
  • Duration: 0:34
  • Updated: 22 May 2015
  • views: 3233
videos
https://wn.com/Pre_Action_System
Nitrogen Generator System on a Preaction Fire Sprinkler System
1:02

Nitrogen Generator System on a Preaction Fire Sprinkler System

  • Order:
  • Duration: 1:02
  • Updated: 05 Nov 2013
  • views: 2360
videos
This is a video of a Installed Nitrogen generator which is being used to supply air pressure for multiple Preaction Fire Sprinkler Systems.
https://wn.com/Nitrogen_Generator_System_On_A_Preaction_Fire_Sprinkler_System
Water fire sprinkler in action
0:29

Water fire sprinkler in action

  • Order:
  • Duration: 0:29
  • Updated: 13 Jul 2012
  • views: 3804
videos
This is what happens when a fire sprinkler breaks.
https://wn.com/Water_Fire_Sprinkler_In_Action
5 year sprinkler inspection...This is a RISER
5:51

5 year sprinkler inspection...This is a RISER

  • Order:
  • Duration: 5:51
  • Updated: 24 Oct 2009
  • views: 28963
videos
Recorded on October 22, 2009 using a Flip Video camcorder.
https://wn.com/5_Year_Sprinkler_Inspection...This_Is_A_Riser
Viking Single Interlock Preaction System - System Reset Procedure
4:50

Viking Single Interlock Preaction System - System Reset Procedure

  • Order:
  • Duration: 4:50
  • Updated: 05 Oct 2011
  • views: 31075
videos
System Reset Procedure for the Viking Single Interlock Preaction System. More information available at www.vikinggroupinc.com.
https://wn.com/Viking_Single_Interlock_Preaction_System_System_Reset_Procedure
Gemini Pre-action Sprinkler Head - Simpleshow
2:33

Gemini Pre-action Sprinkler Head - Simpleshow

  • Order:
  • Duration: 2:33
  • Updated: 31 Jan 2017
  • views: 463
videos
Placing water-based fire retardants in areas with electronics, archives, art and other high-value goods was a major worry… until now. Gemini allows the use of sprinklers in areas where accidental release would cause damage. It acts as a ‘doubleknock’ system and will only release water when both heads have been activated. For more information visit www.geminipreaction.info
https://wn.com/Gemini_Pre_Action_Sprinkler_Head_Simpleshow
Fire Sprinkler Systems Inspection & Service
1:55

Fire Sprinkler Systems Inspection & Service

  • Order:
  • Duration: 1:55
  • Updated: 26 Jul 2017
  • views: 2126
videos
Vancouver Fire Sprinkler System Inspection & Service http://www.bartecfire.com/sprinkler-repair-service/ Sprinklers provide a vital role in protecting a building from fire. When testing a dry sprinkler system, a technician will simulate sprinkler head activation by opening an inspector’s test located at the farthest point of the system. Another technician will observe the activation of the valve in the mechanical room. Once the valve is activated the trip timing and pressures are recorded before the valve is closed and drained. The cover plate can then be removed and the interior of the valve inspected. If the clapper and seat are in good condition and free of debris the valve can be reset and depressurized. The fire alarm panel is checked to confirm alarm and supervisory signals were received. Sprinkler heads and piping are visually inspected condition, correct orientation, type and installation. While testing a wet sprinkler system the control valve is closed causing a supervisory signal which is confirmed by a technician at the fire panel. Once received the test valve is returned to normal and the test drain is opened to flow water simulating the activation of a sprinkler head. The technician observes the flow pressure and times the simulation until the alarm signal is received at the fire panel. Operation and timing is recorded on the inspection report. Although wet and dry sprinklers are the most common there are several other specialized systems to protect property and equipment. Whether your building is new or old, has a deluge, pre-action or special suppression system, Bartec has the expert technicians to keep you protected. Servicing Abbotsford, Burnaby, Chilliwack, Coquitlam, Delta & Tsawwassen, Langley City & District, Maple Ridge, New Westminster, North Vancouver City & District, Pitt Meadows, Port Coquitlam, Port Moody, Richmond, Surrey, Squamish, Vancouver, West Vancouver and the whole Lower Mainland. contact us at: Bartec Fire Safety Systems Ltd 8561 Government Street, Burnaby, BC V3N 4S9 604-420-2964 #firesprinklersysteminspection #firesprinklersystemservice #bartecfire
https://wn.com/Fire_Sprinkler_Systems_Inspection_Service
×